Preliminary Product Listing
PMI Model No. PLM-8G12G-STE-MCCP-PR is a prototype "Proof of Concept" Link Module for special test equipment. It is designed to operate over the 8.0 to 12.0 GHz frequency range. It employs directional couplers, power divider/combiners, a circulator, and extended range DLVA, a threshold detector, and a down link blanking switch. The threshold detector opens the blanking switch whenever an uplink signal is detected, preventing reflected signals at J3 from changing the level at the ERDLVA input.
Quick Links: (click the links below for additional information)
Product Feature
Table 1 Function |
J1 | Up Link |
J2 | ERDLVA Output 75 Ohms |
J3 | Up/Down Link |
J4 | Down Link MSG |
J5 | Uplink MSG |
J6 | UL/DL Monitor |
Table 2 Losses |
Losses | Nominal | Min | Max | ±TOL | Units |
J3-ERDLVA | -20.40 | -17.85 | -22.95 | 2.55 | dB |
J1-ERDLVA | -37.75 | -34.90 | -40.60 | 2.85 | dB |
J1-J5 Up Link Monitor | -21.75 | -20.25 | -23.35 | 1.50 | dB |
J3-J4 Down Link Monitor | -21.80 | -20.25 | -23.35 | 1.55 | dB |
J1-J6 UL/DL Monitor | -43.60 | -39.75 | -47.45 | 3.85 | dB |
J3-J6 UL/DL Monitor | -26.25 | -22.70 | -29.80 | 3.55 | dB |
J1-J3 Up Link | -2.30 | -1.65 | -2.95 | 0.65 | dB |